Inherent CDSS functionalities (numbers of intercepted errors)
 
Inherent CDSS functionalities (numbers of intercepted errors)
 +
 
Drug allergy     833                         109                         <0.001
 
Drug allergy     833                         109                         <0.001
 +
 
Excessive dose     1341                         871                         <0.001
 
Excessive dose     1341                         871                         <0.001
 +
 
Duplication       665                         584                           0.127
 
Duplication       665                         584                           0.127
 +
 
Incomplete or  
 
Incomplete or  
 
unclear order     1976                         663                         <0.001
 
unclear order     1976                         663                         <0.001
 +
  
 
Rules engine software CDSS functionalities
 
Rules engine software CDSS functionalities
 +
 
Colchicine  
 
Colchicine  
 
dosage adjustment 44                         26                           0.078
 
dosage adjustment 44                         26                           0.078
 +
 
Metformin  
 
Metformin  
 
dosage adjustment 101                         66                           <0.001
 
dosage adjustment 101                         66                           <0.001
 +
  
 
CDSS functionalities integrated with pharmacy information systems and laboratory information
 
CDSS functionalities integrated with pharmacy information systems and laboratory information
 +
 
Dose adjustments  
 
Dose adjustments  
 
for renal insufficiency  466                 935                           <0.001
 
for renal insufficiency  466                 935                           <0.001
 +
 
Dose adjustment  
 
Dose adjustment  
 
for drug levels  
 
for drug levels  
 
outside the  
 
outside the  
 
therapeutic range     42                         258                           <0.001
 
therapeutic range     42                         258                           <0.001
 +
  
 
EDDS
 
EDDS
 +
 
Order  
 
Order  
turnaround time 90 minutes     11 minutes
+
turnaround time     90 minutes         11 minutes
 +
 
 
EDDS override rates     7.1%                 2.9%                             <0.001
 
EDDS override rates     7.1%                 2.9%                             <0.001
 +
  
 
BPOC  
 
BPOC  
 +
 
                          Intercepted errors after implementation
 
                          Intercepted errors after implementation
 +
 
Wrong patient           5.5 errors intercepted per 1000 pt-days
 
Wrong patient           5.5 errors intercepted per 1000 pt-days
 +
 
Wrong drug,  
 
Wrong drug,  
 
dose, or route           2.6 errors intercepted per 1000 pt-days
 
dose, or route           2.6 errors intercepted per 1000 pt-days
 +
 
Wrong time           25 errors intercepted per 1000 pt-days
 
Wrong time           25 errors intercepted per 1000 pt-days
 +
  
 
Conclusions:
 
Conclusions:
  
 
Integrated clinical information system technology decreased selected types of medication errors throughout the medication-use process in a single health care system.    These technologies also improved therapeutic drug monitoring in-patient with renal insufficiency and in patients receiving drugs with narrow therapeutic ranges through use of CDSS alerts.
 
Integrated clinical information system technology decreased selected types of medication errors throughout the medication-use process in a single health care system.    These technologies also improved therapeutic drug monitoring in-patient with renal insufficiency and in patients receiving drugs with narrow therapeutic ranges through use of CDSS alerts.
 +
 +
[[Category: BMI-512-F-07]]

Latest revision as of 21:44, 16 November 2011

Background:

Rates of preventable adverse drug events range from 380,000 to 450,000 annually, costing roughly $3.5 billions in hospital cost, resulting in estimated 7000 deaths.

Objective:

This study was designed to evaluate the effect of a vendor-based integrated clinical information system technology on medication errors throughout the medication-use process in a multi-hospital healthcare system.

Setting:

Integrated multi-hospital health care system in Rhode Island.

Interventions:

Implemented Technology – custom integration of the following components

Computer Physician Order Entry (CPOE) – A commercial CPOE system was selected based on ready interoperability with other hospital information system.

Pharmacy information system - A custom interface between the CPOE system and the pharmacy information system was built according to the institution’s requirement. This interface allowed reliable and automatic cross over of medications orders from CPOE and pharmacy information system, thereby assuring the currency of the medication profile.

Clinical Decision Support System - Inherent functionalities of CPOE and pharmacy information system, along with newly developed interface between these components enable 1) drug allergy alerts, duplication alerts, medical dosing support, Two specific rules that were implemented: alerts to clinicians of elevated creatinine (>1.5 mg/dL) when metformin or colchicine were being prescribed. Alerts based on laboratory results and maximum dosing alerts were also possible in this integrated system.

Electronic drug dispensing system (EDDS) - These systems are directly placed on the nursing units and the operating rooms. Except for emergent drugs, a medication cannot be dispensed unless a pharmacist had reviewed and approved the medication order.

Bar-code point-of-care medication administration system (BPOC) - This component offered automatic electronic safeguards for the transcription and administration processes.

Outcomes:

Primary outcome was the reduction in related medication errors. Secondary endpoints included reduction in order turnaround time and automatic dispensing machine override transactions. Selected indicators were used to measure the effects of individual systems and the integrated systems.

Results:

Indicators Preimplementation Post-implementation p-value

Inherent CDSS functionalities (numbers of intercepted errors)

Drug allergy 833 109 <0.001

Excessive dose 1341 871 <0.001

Duplication 665 584 0.127

Incomplete or unclear order 1976 663 <0.001


Rules engine software CDSS functionalities

Colchicine dosage adjustment 44 26 0.078

Metformin dosage adjustment 101 66 <0.001


CDSS functionalities integrated with pharmacy information systems and laboratory information

Dose adjustments for renal insufficiency 466 935 <0.001

Dose adjustment for drug levels outside the therapeutic range 42 258 <0.001


EDDS

Order turnaround time 90 minutes 11 minutes

EDDS override rates 7.1% 2.9% <0.001


BPOC

Intercepted errors after implementation

Wrong patient 5.5 errors intercepted per 1000 pt-days

Wrong drug, dose, or route 2.6 errors intercepted per 1000 pt-days

Wrong time 25 errors intercepted per 1000 pt-days


Conclusions:

Integrated clinical information system technology decreased selected types of medication errors throughout the medication-use process in a single health care system. These technologies also improved therapeutic drug monitoring in-patient with renal insufficiency and in patients receiving drugs with narrow therapeutic ranges through use of CDSS alerts.