Background:

Rates of preventable adverse drug events range from 380,000 to 450,000 annually, costing roughly $3.5 billions in hospital cost, resulting in estimated 7000 deaths.

Objective:

This study was designed to evaluate the effect of a vendor-based integrated clinical information system technology on medication errors throughout the medication-use process in a multi-hospital healthcare system.

Setting:

Integrated multi-hospital health care system in Rhode Island.

Interventions:

Implemented Technology – custom integration of the following components

Computer Physician Order Entry (CPOE) – A commercial CPOE system was selected based on ready interoperability with other hospital information system.

Pharmacy information system - A custom interface between the CPOE system and the pharmacy information system was built according to the institution’s requirement. This interface allowed reliable and automatic cross over of medications orders from CPOE and pharmacy information system, thereby assuring the currency of the medication profile.

Clinical Decision Support System - Inherent functionalities of CPOE and pharmacy information system, along with newly developed interface between these components enable 1) drug allergy alerts, duplication alerts, medical dosing support, Two specific rules that were implemented: alerts to clinicians of elevated creatinine (>1.5 mg/dL) when metformin or colchicine were being prescribed. Alerts based on laboratory results and maximum dosing alerts were also possible in this integrated system.

Electronic drug dispensing system (EDDS) - These systems are directly placed on the nursing units and the operating rooms. Except for emergent drugs, a medication cannot be dispensed unless a pharmacist had reviewed and approved the medication order.

Bar-code point-of-care medication administration system (BPOC) - This component offered automatic electronic safeguards for the transcription and administration processes.

Outcomes:

Primary outcome was the reduction in related medication errors. Secondary endpoints included reduction in order turnaround time and automatic dispensing machine override transactions. Selected indicators were used to measure the effects of individual systems and the integrated systems.


Conclusions:

Integrated clinical information system technology decreased selected types of medication errors throughout the medication-use process in a single health care system. These technologies also improved therapeutic drug monitoring in-patient with renal insufficiency and in patients receiving drugs with narrow therapeutic ranges through use of CDSS alerts.