Difference between revisions of "Meaningful use"

From Clinfowiki
Jump to: navigation, search
(Program Structure)
(Program Structure)
Line 53: Line 53:
  
  
Additional details regarding Stage 1 Core and Menu Objectives is available on the [[Stage 1 CMS webpage]]. [http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Meaningful_Use.html]
+
Additional details regarding Stage 1 Core and Menu Objectives is available on the Stage 1 CMS webpage. [http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Meaningful_Use.html]
  
 
   
 
   
Line 63: Line 63:
  
  
Additional details on the 2011-2013 CQM core and alternative Clinical Quality Measures can be found on the [[CMS CQM webpage]].
+
Additional details on the 2011-2013 CQM core and alternative Clinical Quality Measures can be found on the CMS CQM webpage.
 
[http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/ClinicalQualityMeasures.html]
 
[http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/ClinicalQualityMeasures.html]
  
Line 87: Line 87:
  
  
For additional details regarding the Stage1 & 2 changes to the EP Objectives, please see the [[CMS EP Objective Comparison Table]]. [http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/Stage1vsStage2CompTablesforEP.pdf]
+
For additional details regarding the Stage1 & 2 changes to the EP Objectives, please see the CMS EP Objective Comparison Table. [http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/Stage1vsStage2CompTablesforEP.pdf]
 
   
 
   
For additional details regarding the Stage1 & 2 changes to the EH Objectives, please see the [[CMS EH Ojbective Comparison Table]]. [http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/Stage1vsStage2CompTablesforHospitals.pdf]
+
For additional details regarding the Stage1 & 2 changes to the EH Objectives, please see the CMS EH Ojbective Comparison Table. [http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/Stage1vsStage2CompTablesforHospitals.pdf]
  
  
Line 102: Line 102:
  
  
Additional details regarding the EP Stage 1 & 2 changes to the CQMs starting in 2014, please see the [[CMS 2014 EP Final Rule]].
+
Additional details regarding the EP Stage 1 & 2 changes to the CQMs starting in 2014, please see the CMS 2014 EP Final Rule.
 
[http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/EP_MeasuresTable_Posting_CQMs.pdf]
 
[http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/EP_MeasuresTable_Posting_CQMs.pdf]
  
Additional details regarding the EH Stage1 & 2 changes to the CQMs starting in 2014, please see the [[CMS 2014 EH Final Rule]].
+
Additional details regarding the EH Stage1 & 2 changes to the CQMs starting in 2014, please see the CMS 2014 EH Final Rule.
 
[http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/2014_CQM_EH_FinalRule.pdf]
 
[http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/Downloads/2014_CQM_EH_FinalRule.pdf]
  
  
 
=== Stage 3 ===
 
=== Stage 3 ===
As of March 2013, there are no formal published timelines for Stage 3 nor are there any proposed Core/Menu Set Objectives or Clinical Quality Measures. The focus of the program and of CMS is currently on encouraging participation in the two published stages and also the industry [[transition from ICD9 to ICD-10]]. [http://clinfowiki.org/wiki/index.php/Transitioning_from_ICD-9_to_ICD-10]
+
As of March 2013, there are no formal published timelines for Stage 3 nor are there any proposed Core/Menu Set Objectives or Clinical Quality Measures. The focus of the program and of CMS is currently on encouraging participation in the two published stages and also the industry [[Transitioning from ICD-9 to ICD-10]].  
  
  

Revision as of 18:00, 10 March 2013

Meaningful use is prominently used in Health Information Technology Economy and Clinical Health Act (HITECH) provisions of the American Recovery and Reinvestment Act (ARRA) [1]. It was further defined by the Center for Medicare and Medicaid Services in a way that describes the use of health information technology for use among professionals.

The American Recovery and Reinvestment Act of 2009 authorized the Centers for Medicare & Medicaid Services (CMS) to provide financial incentives to providers and hospitals for adopting meaningful use of certified electronic health record (EHR) technology.

Under this authority the Office of the National Coordinator for Health Information Technology (ONC) has begun to setup standards, implementation specifications, and certification criteria for electronic medical record technology. The final rules should be completed by the end of 2010.

Guideline

The Office of the National Coordinator for Health Information Technology (ONC) has listed the following goals as a guide [2]:

  1. Promote interoperability and where necessary be specific about certain content exchange and vocabulary standards to establish a path forward toward semantic interoperability.
  2. Support the evolution and timely maintenance of adopted standards
  3. Promote technical innovation using adopted standards
  4. Encourage participation and adoption by all vendors, including small businesses
  5. Keep implementation costs as low as reasonably possible
  6. Consider best practices, experiences, policies, frameworks, and the input of the HIT Policy Committee and HIT Standards Committee in current and future standards
  7. Enable mechanisms such as the Nationwide Health Information Network (NHIN) to serve as a test-bed for innovation and as an open-source reference implementation of best practices
  8. To the extent possible, adopt standard that are modular and not interdependent.

The standards to be adopted are based on current industry practices and rely on the following: Health Level 7, Inc (HL-7); National Institute of Standards and Technology (NIST) and Integrating the Health care Enterprise (IHE); SNOMED CT; International Statistical Classification of Diseases (ICD), LOINC, NCPDP and RxNorm.

You may view the entire proposed Electronic Health Record Incentive Program by opening the following pdf file[3] or link[4].

Introduction

In order for eligible providers and hospitals to qualify for federal stimulus dollars, they must use certified electronic health technology in order to measure clinical quality. The United States federal government outlined the proposed criteria to achieve meaningful use in the Medicare and Medicaid Programs; Electronic Health Record Incentive Program; Proposed Rule of January 13, 2010. [5] Most health care organizations are trying to achieve meaningful use although there are struggles. [6] [[7]

Measures of clinical quality

The 25 measures involved in using health information technology for physicians, are separated into 5 initiatives. In order to qualify for stimulus dollars, the eligible provider must meet all the targets specified in the rule during a 90 day reporting period.

Program Structure

The Centers for Medicare and Medicaid Services (CMS) has stated meaningful use can reform the health care system and improve health care quality, efficiency, and patient safety in three stages. [8] Within the 3 stages, the program has gradually increasing requirements for participation. All Eligible Professional and Eligible Hospitals begin participating their first year by meeting the Stage 1 requirements for a 90-day period. They continue to complete Stage 1 certification by participating for a full year. After meeting Stage 1 requirements for a minimum of 1 full year plus the 90-day initial measurement, providers can then quality for Stage 2. Stage 2 also requires a 90-day measurement period followed by a full year of participation at which point the Eligible Providers and Eligible Hospitals will have qualified for Stage 2 certification. Note that measuring length of participation, Eligible Providers will use the calendar year, while Eligible Hospitals use their fiscal year.

The program structure includes both a core and a menu set of objectives with specific requirements for achieving Meaningful Use for both Eligible Professionals (EP)and Eligible Hospitals (EH). Additionally, Eligible Professionals and Eligible Hospitals are also required to report Clinical Quality Measures.

  • Core Objectives are a list of measures that must all be achieved.
  • Menu Objectives are a list of measures where a portion of the measure must be achieved.
  • Clinical quality measures (CQMs) consist of a combination of required core measures and alternative measures.

Note the list of Core/Menu Set Objectives and Clinical Quality Measures can change based on EP or EH status, Stage of the program and year of participation.

Stage 1

Core and Menu Set Objectives

Eligible Professionals: There are a total of 25 meaningful use objectives. To qualify for an incentive payment, all 15 core objectives must be achieved along with 5 of the 10 menu set objectives.

Eligible Hospitals: There are a total of 24 meaningful use objectives. To qualify for an incentive payment, all 14 core objectives must be achieved along with 5 of the 10 menu set objectives.


Additional details regarding Stage 1 Core and Menu Objectives is available on the Stage 1 CMS webpage. [9]


Clinical Quality Measures

Eligible Professionals: EPs must report on 6 total clinical quality measures comprised of 3 required core measures (or 3 alternate core measures) and 3 additional measures (selected from a set of 38 clinical quality measures).

Eligible Hospitals: EHs must report on all 15 core clinical quality measures.


Additional details on the 2011-2013 CQM core and alternative Clinical Quality Measures can be found on the CMS CQM webpage. [10]


Note for Stage 1 attestation in 2013, no changes have been made to the Clinical Quality Measure as originally published to meet Stage 1 in 2011 or 2012. However, starting in 2014, Stage 1 attestation will require reporting based on the 2014 CQMs finalized as part of Stage 2. (see below Stage 2 CQMs)


Stage 2

In order to participate in Stage 2, the Eligible Professional or Eligible Hospital must have met the achieved Stage 1 certification.


Core and Menu Set Objectives

Eligible Professionals: There are a total of 23 meaningful use objectives. To qualify for an incentive payment, all 17 core objectives must be achieved along with 3 of the 6 menu set objectives.

Eligible Hospitals: There are a total of 22 meaningful use objectives. To qualify for an incentive payment, all 16 core objectives must be achieved along with 3 of the 6 menu set objectives.


For both EP and EH, you will notice some changes to the Core and Menu Set Objectives including:

  • Some objectives have been “retired” from the program altogether, affecting both Stage 1 in 2013 forward as well as Stage 2
  • Some objectives have moved from the Menu Set to the Core Set and in some cases combined with pre-existing objectives
  • New objectives have been added to both the Core and Menu Set, while some of the original objectives remain in both categories with higher thresholds to meet the objective


For additional details regarding the Stage1 & 2 changes to the EP Objectives, please see the CMS EP Objective Comparison Table. [11]

For additional details regarding the Stage1 & 2 changes to the EH Objectives, please see the CMS EH Ojbective Comparison Table. [12]


Clinical Quality Measures

In Stage 2, CQMs are no longer part of the core measure objective set, however EPs and EHs are required to continue to set them based on the Stage 2 rules. In addition to these new CQMs, all EPs and EHs beyond their first year of meaningful use will be required to submit this data electronically.


Eligible Professionals: EPs must report on 9 our of the 64 approved clinical quality measures. A minimum of 3 of the selected CQMs must also cover the National Quality Strategy domains. There is also a set of core CQMs that are recommended, although not required.

Eligible Hospitals: EHs must report on 16 out of 29 approved core clinical quality measures. As with the EP requirement, a minimum of 3 of the selected CQMs must also cover the National Quality Strategy domains.


Additional details regarding the EP Stage 1 & 2 changes to the CQMs starting in 2014, please see the CMS 2014 EP Final Rule. [13]

Additional details regarding the EH Stage1 & 2 changes to the CQMs starting in 2014, please see the CMS 2014 EH Final Rule. [14]


Stage 3

As of March 2013, there are no formal published timelines for Stage 3 nor are there any proposed Core/Menu Set Objectives or Clinical Quality Measures. The focus of the program and of CMS is currently on encouraging participation in the two published stages and also the industry Transitioning from ICD-9 to ICD-10.


Submitted by Paula Cottrell

First Initiative: Improve quality, safety, efficiency, and reduce health disparities

  1. Use CPOE for all orders for 80% of orders
  2. Enable drug based alerts
  3. Maintain an up-to-date problem list of current and active diagnoses for 80% of patients
  4. E-prescribe for 75% of prescriptions
  5. Maintain an active medication list for 80% of patients
  6. Maintain an active allergy list for 80% of patients
  7. Record structured demographic data for 80% of patient
  8. record vital signs in the EMR for 80% of patients
  9. Record smoking status of 80% of patients
  10. Incorporate laboratory testing as structured data 50% of the time
  11. Generate a list of patients for quality improvement or outreach
  12. Report ambulatory quality data to the Center for Medicaid and Medicare services
  13. Send reminders to patients per their preference for 50% of patients
  14. Implement 5 clinical decision support rules
  15. check insurance eligibility electronically for 80% of patients
  16. Submit claims electronically for 80% of patients

Second initiative: Engage patients and their families

  1. Provide 80% of patients who request it, a copy of their health information within 48 hours
  2. Provide 10% of all patients with electronic access to to their health data within 96 hours of its availability.
  3. Provide 80% of patients a clinical summary of their visit

Third initiative :Improve care coordination

  1. Demonstrate the ability to electronically share clinical information between organizations
  2. Perform medication reconciliation for 80% of encounters
  3. Provide a summary of care record for 80% of referrals and transitions in care

Fourth initiative: Improve Population and Public Health

  1. Demonstrate electronic submission of immunization to state immunization registries
  2. Demonstrate the ability to exchange information with public health agencies

Fifth Initiative: Ensure Adequate Privacy and Security Protections for Personal Health Information

  1. Protect electronic health information by implementing appropriate technologies.

The interim rule goes on to state that physicians will be required to report on a subset of 90 clinical quality measures related to specialty.(5) The exact quality measures to be selected, and modifications to the use metrics will be available late in the spring of 2010 when the final rule is published.

The Impact of Meaningful Use

Many eligible healthcare professionals are scrambling to meet the meaningful use criteria and deadlines for many reasons; primarily to maximize Medicare and Medicaid reimbursements, leverage technology to provide better patient care and create efficiencies in prescribing, registry reporting, transition of care and medical records management.4

Knowing full well that implementing an electronic health record system and consequently proving meaningful use will require resources to accomplish, with the focus on the implementation factor, the impact to healthcare support services such as the medical records department, has been overlooked or, if known, ignored.

Meaningful use definition

“Meaningful use is ultimately linked to achieving measurable outcomes in patient engagement, care coordination, and population health.”1 Meaningful use is being defined by the Centers for Medicare and Medicaid Services as “how to best frame (these) measures including measurement of key public health conditions, measuring health care efficiency, and measuring the avoidance of certain adverse events.” 1

Meaningful use measures with impact on support services Measure: Record Advance Health Care Directive (AHCD) Stage 1: 50% (hospital requirement only). Make core requirement. For EP and EH: 50% of patients >=65 years old have recorded in the electronic health record (EHR) the result of an advance directive discussion and the directive itself if it exists. 2

Impact

Advance health care directives are legal documents, which allow the patient to chose his or her end-of-life decisions ahead of time.3 50% of all admitted patients 65+ should have documented in their health record that there was a discussion about, or documentation of, an advance directive. Hospitals have been actively pursuing this meaningful use criteria as it is seems to be an easy goal to accomplish because the time and effort to implement this procedure electronically appears minimal with low impact to the workflow. However, the unexpected consequence of implementing this criterion without full workflow process analysis proved to negatively impact clinical support services at healthcare facilities. Colleena Kirby, the legal documents processor in the medical records administration department at a large health maintenance organization in Hawaii reports that there was an average of 10 AHCD per day pre-meaningful use. Post-meaningful use implementation about 60 AHCD per day arrives for processing.5 The AHCD workflow consists of filtering for errors, rejecting erroneous AHCD, sending out rejection letters, scanning, indexing and documenting the AHCD. This process took approximately two hours a day for 10 AHCD. With the number increasing to 60 per day, the processing of AHCD was creating a backlog of all other documentation processing and was requiring resources which were not available to the medical records administration department. Consequently all legal documents processing started backlogging, which impacted patient care, revenue cycle and legal departments.5

How clinical information systems can help: The use of the EHR can be used by healthcare providers to document that a conversation regarding AHCD was discussed with the patient, which also qualifies as part of the 50% of AHCD for meaningful use. However, many providers and facilities will accept the paper document and send to the medical records administration, or scanning department, to process and scan in the document itself as proof of discussion of the AHCD. Document management systems which utilize a scan-on-demand function, which can feed scans into the EHR via fax or PDF, can help integrate the paper and electronic records, alleviating the impact to support services departments while not requiring more full-time resources to complete the work and also fulfilling meaningful use criteria.

References:

  1. U.S. Department of Health and Human Services The Office of the National Coordinator for Health Information Technology. Meaningful use: a definition. 2009. Available from URL: http://healthit.hhs.gov/portal/server.pt?open=512&objID=1325&mode=2. Accessed 2011 May 21.
  2. U.S. Department of Health and Human Services The Office of the National Coordinator for Health Information Technology. Meaningful use matrix. 2009. Available from URL: http://healthit.hhs.gov/portal/server.pt/document/872719/meaningful_use_matrix_pdf. Accessed 2011 May 21.
  3. Medline Plus. Advance directives. Available from URL: http://www.nlm.nih.gov/medlineplus/advancedirectives.html. Accessed 2011 May 21.
  4. Healthcare Information and Management Systems Society. The consequences of not pursuing meaningful use. 2010. Available from URL: http://www.himss.org/ASP/topics_News_item.asp?cid=74732&tid=9. Accessed 2011 May 21.
  5. Kirby C. [Personal interview, 15 May] Honolulu; 2011 (unpublished).


Submitted by: Lari Anne Kamei


References

  1. Stimulus : American Recovery and Reinvestment Act of 2009 Public Law 111-5 Official Text. Lanham, MD: Government Institutes / Bernan Press; 2009.
  2. CMS. Medicare and Medicaid Programs; Electronic Health Record Incentive Program. Proposed Rule. Fed Regist; 2010. p. 1844-2011
  3. Lewis P. "Meaningful Use" takes time (HIMSS 2010 conference). In: amednews: American Medical News; 2010.
  4. Kennedy D. [15] Small, Mid-Sized, Physician practices Could Face Barriers in Meeting 'Meaningful Use' Criteria. iHealthBeat 2010:1.
  5. Heubusch. [16] Clinical Quality Measures for Providers. J AHIMA 2010.
  6. [17][18]